| Technical data | Values/parameters | DIN |
| Dimensions Standard panel size Maximum panel size |
1200 x 900 [mm], thickness 20 [mm] 2780 x 1260 [mm], thickness 20 [mm] |
|
| Dimensional
tolerances Dimensions Thickness |
±1,20 [mm] ±1,00 [mm] high polish ±1,20 [mm] hammered finish |
|
| Specific gravity | Approx. 2,4 [g/cm³] | |
| Weight per m² with 20mm thickness | Approx. 48,00 [kg] | |
| Bending strength Characteristic value 5% fractile |
Approx. 28 [MPa] Approx. 22 [MPa] |
DIN 52112 |
| Tearing strength
attachment point {anchors attached to the rear from the firm of Keil, placement depth 13 mm} |
Approx. 3,2 [KN] {average value} | |
| Elasticity module | Approx. 57 [kN/mm²] average value | |
| Hardness According to Mohs According to Vickers HV |
5 5-6 [GPa] |
DIN EN 101 |
| Heat expansion 20-100ºC | 7,22 [10 -6/K] | DIN EN 103 |
| Heat conductivity at 64ºC | 1,04 [W/m K] | |
| Specific heat capacity Cp | 0,7 [J/g K] | |
| Water absorption | < 0,1 [Ma.-%] | DIN EN 99 |
| Frost resistance | No trials with visible defects | DIN
EN 202 |
| Stain resistance | Class 1 | DIN EN 122 |
| Chemical resistance | Class AA | DIN EN 122 |
| Acid resistance | Class AA | DIN EN 122 |
| Caustic resistance | Class A | DIN EN 122 |
| Fire class | Class A | DIN 4102 |
| Surface wear | Class II, 300 revolutions | DIN EN 154 |
| Slip resistance | R 9 { with hammered-finished surface} | DIN 51130 |
| Surface area | High polish or hammered finish | |
| Surface properties | Closed surface, therefore easy removal of graffiti, cleaning with all traditional cleaning agents and solvents | |
| Colour and light fastness | Colour and light fastness thanks to use of high-grade inorganic colour pigments | |
| Edge finish | -
all panels are supplied with facetted edges - polished edges or other processing options on request (for example, half- round) |
|
| Application / processing | Cladding
unit for curtain walls with ventilation at the back (VHF). Interior
wall covering, in sanitary facilities etc. - In the factory the panels are sawn to size, facetted and provided with drill holes according to specification parts list - Alternative fixing options (e.g. gluing, edge fastening etc.) on request |
|
| Finish | Structuran® glass ceramics can, under certain conditions, be sawn and drilled with water-cooled diamond tools at the construction site | |
| Environment | Structuran® glass ceramics is 100% recyclable | |
| Approval: (required when using structuran® glass ceramics suspended cladding unit) | -
general approval by building inspection for panel sizes up to 1200 x
900 [mm], granted on 24-01-2000 under no. Z-33.1-379 - for large panel sizes the “approval in specific cases“ has been granted on several occasions |
|
This technical
information leaflet has been compiled in accordance with the current
technical level and the experience of the firm Indupart Europe BV with
the material Structuran® -glass ceramics. It does not discharge the
user of the obligation to check this material accurately for its suitability
for its intended use and the object circumstances concerned. This information
leaflet is kept permanently up-to-date, which means that all previous
editions will become invalid. |
||